We attract customers by our fabulous CDCP certification material and high pass rate, which are the most powerful evidence to show our strength. We are so proud to tell you that according to the statistics from our customers’ feedback, the pass rate of our CDCP exam questions among our customers who prepared for the exam with our CDCP Test Guide have reached as high as 99%, which definitely ranks the top among our peers. Hence one can see that the CDCP learn tool compiled by our company are definitely the best choice for you.
EXIN CDCP Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
Topic 5
Topic 6
Topic 7
Topic 8
>> Valid Braindumps CDCP Ppt <<
CDCP Test Vce - Reliable CDCP Dumps Files
Our CDCP study tools not only provide all candidates with high pass rate study materials, but also provide them with good service. If you have some question or doubt about us or our products, you can contact us to solve it. The thoughtfulness of our CDCP study guide services is insuperable. What we do surly contribute to the success of CDCP practice materials.We all know that it is of great important to pass the CDCP Exam and get the certification for someone who wants to find a good job in internet area. I will recommend our study materials to you. It can be said that our CDCP test prep greatly facilitates users, so that users cannot leave their homes to know the latest information.
EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q49-Q54):
NEW QUESTION # 49
What factor should be considered when placing fluorescent lighting in the data centre?
Answer: B
Explanation:
The UPS (uninterruptible power supply) is a device that provides backup power to the ICT equipment in case of a power outage or a power quality issue. The UPS should be dedicated to the ICT equipment only, and not to other loads, such as lighting, cooling, or security systems. This is because connecting fluorescent lights to the same UPS as the ICT equipment can cause several problems, such as:
*Reducing the battery runtime of the UPS, which may not be enough to support the ICT equipment until the backup generator kicks in or the utility power is restored.
*Increasing the harmonic distortion of the UPS output, which can affect the performance and reliability of the ICT equipment and the UPS itself.
*Creating electromagnetic interference (EMI) or radio frequency interference (RFI), which can disrupt the communication and data transmission of the ICT equipment.
*Triggering false alarms or tripping the circuit breakers of the UPS, which can cause downtime or data loss.
Therefore, fluorescent lights should not be connected to the same UPS that supports the ICT equipment.
Instead, they should be connected to a separate power source, such as the utility power, the backup generator, or a different UPS.
References:
1: CDCP Preparation Guide, page 17, section 2.3.1 2: Data Center Lighting Design Considerations3, page 1, section 3 4: Data Center Lighting Solutions5, page 1, section 1 6: Going beyond energy savings in data centers with LEDs7, page 1, section 2
NEW QUESTION # 50
When having two non-synchronized power sources, the ATS / STS need to be of the type:
Answer: D
Explanation:
When having two non-synchronized power sources, the ATS / STS need to be of the type break before make, which means that the switch disconnects from one source before connecting to the other source. This prevents any short circuit, back feed, or phase mismatch that could occur if the two sources were connected simultaneously. Break before make switches are also known as open transition switches, because they create a brief interruption in the power supply during the switching process. This interruption is usually acceptable for most ICT equipment, as they have internal power supplies or batteries that can handle the transient. However, if the interruption is not acceptable, then the two power sources need to be synchronized before switching, which requires a make before break switch, also known as a closed transition switch. Make before break switches connect to the second source before disconnecting from the first source, which ensures a seamless transfer of power without any interruption. However, make before break switches require that the two sources have the same voltage, frequency, and phase, which can be achieved by using a synchronization module or a phase-locked loop.
References:
1: CDCP Preparation Guide, page 17, section 2.3.1 2: STS in data centres - Borri3, page 1, section 1 4: Using Static Transfer Switches to Enhance Data Center ... - Donwil5, page 1, section 1 6: What is an Automatic Transfer Switch (Power)? | Ethan Banks7, page 1, section 1
NEW QUESTION # 51
What is the minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems?
Answer: C
Explanation:
The minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems is 46 cm / 18 inches, according to the CDCP Preparation Guide1 and OSHA regulation 29 CFR
1910.159 (10)2. This clearance space is necessary to ensure that the sprinkler spray or gas discharge can reach the fire and cover the protected area effectively. Any material or obstruction below this clearance space can interfere with the sprinkler or gas distribution and reduce the fire suppression performance. Therefore, building owners and managers should ensure that all storage and objects in the data centre are kept below this clearance space, and that the clearance space is maintained at all times.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Clarification of OSHA regulation 29 CFR 1910.159 (10), Sprinkler ...3, page 1, section 1
NEW QUESTION # 52
Which one of the following is an Audible Signaling and Notification Device?
Answer: A
Explanation:
According to the CDCP Preparation Guide, an audible signaling and notification device is a device that produces a sound to alert or notify the occupants of a data center of an event or condition. Sirens are examples of such devices, as they can emit loud and distinctive tones to warn of fire, emergency, or security incidents.
Strobes, on the other hand, are visual signaling and notification devices that produce flashes of light to attract attention or convey information. Alarms and clocks are not specific types of devices, but rather general terms that can refer to various audible or visual devices.
References: CDCP Preparation Guide, page 30. Audible Visual Notification | System Sensor | Honeywell.
Audible-Visual Signaling Devices - AutomationDirect.
NEW QUESTION # 53
is the arithmetic mean of time between the failing and the subsequent running of the system in a particular time period.
Answer: A
Explanation:
MTBF stands for Mean Time Between Failures, and it is the arithmetic mean of time between the failing and the subsequent running of the system in a particular time period. MTBF is a measure of reliability that indicates how often a system or component fails during its operation. MTBF can be calculated by dividing the total operating time by the number of failures over a given period. For example, if a system operates for 1000 hours and experiences 5 failures, the MTBF is 1000/5 = 200 hours.
References: EPI Data Centre Training Framework, CDCP Preparation Guide, MTBF, MTTR, MTTF, MTTA:
Understanding incident metrics - Atlassian
NEW QUESTION # 54
......
Managing time during the EXIN CDCP exam is a challenging task. Most candidates cannot manage their time during the EXIN CDCP exam, leave the questions, and fail. Time management skills can help students gain excellent marks in the CDCP Exam. EXIN CDCP practice exam on the software help you identify which kind of CDCP questions are more time-consuming, and they would be able to assess their efficiency in answering questions.
CDCP Test Vce: https://www.testvalid.com/CDCP-exam-collection.html
BTW, DOWNLOAD part of TestValid CDCP dumps from Cloud Storage: https://drive.google.com/open?id=1Qnej4MtgzBoXUM3jkKYj0U691hfNySSt
©2024 All rights reserved
WhatsApp us